Basic Info.
Model NO.
40A
Operation
Electric
Certification
CE, ISO9001
Type
Integrated automatic transfer switch
Poles
4P
Output type
AC
Product Name
ATS
Certificate
Ce / ISO9001
Keyword
Automatic Transfer Switch
Agreed Thermal Current Ith
40A
Rated Insulation Voltage Ui
750V
Rated Impulse Withstand Voltage Uimp
8kv
Rated Work Voltage Ue
AC440V
Rated Connection Capacity
10le
Rated Breaking Capacity
8le
Rated Conditional Short-Circuit Current
100ka
Transport Package
Carton
Specification
7.2
Trademark
suyang
Origin
China
HS Code
8503009090
Production Capacity
80000sets/Month
Product Description
ATS Agreed Thermal Current Ith 40A Three Phase Automatic Transfer Switch
ATS INTRODUCTIhhON
I. Product Characteristics:
1. Such technologies as double-row composite contact, horizontal pull-type mechanism, micro-motor pre-stored energy and micro-electronic control have been adopted, achieving basically zero flashover, in which logic control boards are mounted to manage. In different logic, the operation of the running of the motor and the speed change box installed directly in the switch, so as to ensure the positions of the switch.
2. A duplex interlocking design of both mechanical and electric interlocking is adopted.
3. A zero position technology is adopted, so as to reset to zero compulsorily under an emergency case (both the two power supplies are cut off)
4. Automatic transfer switches have such functions as obvious ON/OFF position indication and padlock, so as to realize isolation between power supply and load.
5. The motor is a poly chloroprene rubber insulation damp-heat type equipped with a safety device, which trips off automatically, when there is over-temperature above 110ºC and over-current, and is put into service automatically, when the trouble is removed. A straight-tooth gear is adopted for the reversible reduction gear.
6. The outer casing is made of unsaturated polyester fibers, which are high in fire, pressure and high temperature resistance.
II. Applicable Standards:
1. IEC60947-1/GB/T·14048.1-2008<General Provisions for Low-voltage Switch Gears and Control Equipment>
2. IEC60947-3/GB·14048.3<Low-voltage Switch Gears and Control Equipment: Low Voltage Switches, Isolators, Isolation Switches and Fuse Combiners>
3. IEC60947-6-1/GB·14048.11<Automatic transfer Switchgear>
III. Main Technical Parameters:
![ATS Agreed Thermal Current Ith 40A Three Phase Automatic Transfer Switch](http://img9.grofrom.com/www.yselectricgroup.com/226f3j00OreQDCMhgEbz/ATS-Agreed-Thermal-Current-Ith-40A-Three-Phase-Automatic-Transfer-Switch.webp)
![ATS Agreed Thermal Current Ith 40A Three Phase Automatic Transfer Switch](http://img9.grofrom.com/www.yselectricgroup.com/226f3j00ngvtLKesCacp/ATS-Agreed-Thermal-Current-Ith-40A-Three-Phase-Automatic-Transfer-Switch.webp)
![ATS Agreed Thermal Current Ith 40A Three Phase Automatic Transfer Switch](http://img9.grofrom.com/www.yselectricgroup.com/226f3j00nueQIFCSZaqg/ATS-Agreed-Thermal-Current-Ith-40A-Three-Phase-Automatic-Transfer-Switch.webp)
ATS INTRODUCTIhhON
I. Product Characteristics:
1. Such technologies as double-row composite contact, horizontal pull-type mechanism, micro-motor pre-stored energy and micro-electronic control have been adopted, achieving basically zero flashover, in which logic control boards are mounted to manage. In different logic, the operation of the running of the motor and the speed change box installed directly in the switch, so as to ensure the positions of the switch.
2. A duplex interlocking design of both mechanical and electric interlocking is adopted.
3. A zero position technology is adopted, so as to reset to zero compulsorily under an emergency case (both the two power supplies are cut off)
4. Automatic transfer switches have such functions as obvious ON/OFF position indication and padlock, so as to realize isolation between power supply and load.
5. The motor is a poly chloroprene rubber insulation damp-heat type equipped with a safety device, which trips off automatically, when there is over-temperature above 110ºC and over-current, and is put into service automatically, when the trouble is removed. A straight-tooth gear is adopted for the reversible reduction gear.
6. The outer casing is made of unsaturated polyester fibers, which are high in fire, pressure and high temperature resistance.
II. Applicable Standards:
1. IEC60947-1/GB/T·14048.1-2008<General Provisions for Low-voltage Switch Gears and Control Equipment>
2. IEC60947-3/GB·14048.3<Low-voltage Switch Gears and Control Equipment: Low Voltage Switches, Isolators, Isolation Switches and Fuse Combiners>
3. IEC60947-6-1/GB·14048.11<Automatic transfer Switchgear>
III. Main Technical Parameters:
Agreed thermal current Ith | 20A | 40A | 63A | 80A | 100A | 125A | 160A | 250A | 400A | 630A | 800A | 1000A | 1250A | 1600A | 2000A | 2500A | 3200A | |||
Rated insulation voltage Ui | 750V | 1000V | ||||||||||||||||||
Rated impulse withstand voltage Uimp | 8KV | 12KV | ||||||||||||||||||
Rated work voltage Ue | AC440V | |||||||||||||||||||
Rated work current Ie | AC-31A | 20 | 40 | 63 | 80 | 100 | 125 | 160 | 250 | 400 | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 3200 | ||
AC-35A | 20 | 40 | 63 | 80 | 100 | 125 | 160 | 250 | 400 | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 3200 | |||
AC-33A | 20 | 40 | 63 | 80 | 100 | 125 | 160 | 250 | 400 | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 3200 | |||
Rated connection capacity | 10Ie | |||||||||||||||||||
Rated breaking capacity | 8Ie | |||||||||||||||||||
Rated conditional short-circuit current | 100KA | 70KA | 100KA | 120KA | 80KA | |||||||||||||||
Rated short-time withstand current IS | 7KA | 9KA | 13KA | 26KA | 50KA | 55KA | ||||||||||||||
Transferring time I-II or II-I | 0.45S | 0.6S | 1.2S | 2.4S | ||||||||||||||||
Control power supply voltage | DC24V, 48V, 110V; AC220V,AC380V | |||||||||||||||||||
Energy consumption of motor | ||||||||||||||||||||
Rated control voltage | Start up | 300W | 325W | 355W | 400W | 440W | 600W | |||||||||||||
Normal | 55W | 62W | 74W | 90W | 98W | 120W | ||||||||||||||
Weight(kg) | SKX1/T1 | 7.2 | 7.2 | 7.2 | 7.2 | 7.2 | 7.2 | 8.8 | 9 | 18.5 | 19 | 43 | 43 | 43 | 51 | 118 | 118 | 135 | ||
SKT2/X2 | 3.9 |