Basic Info.
Model NO.
NV-ATS11KW
Condition
New
Certification
CE, RoHS, FCC
Application
Solar System Controller, Charger Controller, Lighting Controller, Wind Controller, Solar Working Station
Rated Voltage
12/24V Auto
Default Bat. Low Recovery
13.5V / 27V / 54V (Adju
Battery Input Voltage
12 / 24 / 48 VDC Auto
Carton Quantity
12 PCS/CTN
Transport Package
Gift Box
Specification
52*45.5*37.5cm, 18.2KG/ctn
Trademark
NOVA
Origin
China, Zhejiang
Production Capacity
5000
Packaging & Delivery
Package Size
25.00cm * 30.00cm * 17.00cm
Package Gross Weight
1.500kg
Lead Time
7 days (1 - 100 Pieces)
To be negotiated ( > 100 Pieces)
To be negotiated ( > 100 Pieces)
Product Description
![Transfer Controller Generation Inverter Changeover Switch Solar and Grid Automatic Transfer Switch 220V 110V](http://img9.grofrom.com/www.yselectricgroup.com/226f3j00dSWLAIJRkjGz/Transfer-Controller-Generation-Inverter-Changeover-Switch-Solar-and-Grid-Automatic-Transfer-Switch-220V-110V.webp)
Product | Intelligent Dual Power Transfer Switch (ATS) |
Application | Way of connection 1: "Off-grid Solar/Wind ---- Grid Power" transfer Way of connection 2: Intelligent battery combiner |
Model | NV-ATS11KW |
Length/Weight | Product Size: 19*14.5*7cm 1.25KG Inner Box: 25.5*21.8*12cm Outer Carton: 52*45.5*37.5cm 12 pcs/ctn, 18.2KG/ct |
![Transfer Controller Generation Inverter Changeover Switch Solar and Grid Automatic Transfer Switch 220V 110V](http://img9.grofrom.com/www.yselectricgroup.com/226f3j00wjlIAkmnisYz/Transfer-Controller-Generation-Inverter-Changeover-Switch-Solar-and-Grid-Automatic-Transfer-Switch-220V-110V.webp)
![Transfer Controller Generation Inverter Changeover Switch Solar and Grid Automatic Transfer Switch 220V 110V](http://img9.grofrom.com/www.yselectricgroup.com/226f3j00AslIJjmcPSGu/Transfer-Controller-Generation-Inverter-Changeover-Switch-Solar-and-Grid-Automatic-Transfer-Switch-220V-110V.webp)
Item | Description |
NV-ATS11KW | Battery Voltage:12 / 24 / 48 VDC Auto Input Voltage: 110 / 220 VAC Auto Max Current: 50A Max Power: 5.5KW (110VAC system) or 11KW (220VAC system) Inverter transfer to public power: ≤ 10ms Public power/generator transfer to inverter: ≤ 16ms Default BAT. Low Cut-down: 11V / 22V / 44V (Adjustable) Default BAT. Low Recovery: 13.5V / 27V / 54V (Adjustable) Battery low cut-down & recovery voltage adjustable according to different battery types LCD Display: Working status of Public Power, Inverter and Battery Battery Type: Suits to any kind of battery whose voltage are within 9-17V (12VDC system), 18-30V (24VDC system), or 30-60V (48VDC system). |
![Transfer Controller Generation Inverter Changeover Switch Solar and Grid Automatic Transfer Switch 220V 110V](http://img9.grofrom.com/www.yselectricgroup.com/226f3j00AjiHJdmrpsRu/Transfer-Controller-Generation-Inverter-Changeover-Switch-Solar-and-Grid-Automatic-Transfer-Switch-220V-110V.webp)
![Transfer Controller Generation Inverter Changeover Switch Solar and Grid Automatic Transfer Switch 220V 110V](http://img9.grofrom.com/www.yselectricgroup.com/226f3j00EsiImGAhnZYL/Transfer-Controller-Generation-Inverter-Changeover-Switch-Solar-and-Grid-Automatic-Transfer-Switch-220V-110V.webp)
-- It connects "off grid solar/wind/hydro system" and "public power/generator" in the same circuit. -- Works as Opposite UPS: battery power priority, public power second
-- ATS transfers according to battery voltage. 1. Priority Power source: Inverter AC <--- Battery <---- Solar/Wind. 2. Only when battery low, it auto transfers to Second Power source: Grid AC / Generator / Standby Battery-Inverter Pack. 3. When battery recovers, it auto transfers back to Priority Power source.
Advantage
1. In rainy, cloudy, windless days, the off grid solar/wind system can not generate enough electricty. ATS can solve electricty storage limitation problem of off-grid solar system, or when main battery pack of your RV or boat get problem. To keep your electricity 24-hour long.
Advantage
1. In rainy, cloudy, windless days, the off grid solar/wind system can not generate enough electricty. ATS can solve electricty storage limitation problem of off-grid solar system, or when main battery pack of your RV or boat get problem. To keep your electricity 24-hour long.
2. Fast Change-over: Inverter transfer to public power ≤ 10ms, public power/generator transfer to inverter ≤ 16ms. No power "flickering", loads do not shut off, work all times as if no power changeover.
3. Prevent battery from over-discharging, extend batteries' life.
4. Save electricty bill by at lease 30%. Utilize solar power and rely less on the public power company.
5. No need spend huge money $34K for grid-tie system.
6. Easy Installation. DIY. No need to cut into public power, or any factory wiring that may void the manufacturer's warranty of your boat or vehicle
![Transfer Controller Generation Inverter Changeover Switch Solar and Grid Automatic Transfer Switch 220V 110V](http://img9.grofrom.com/www.yselectricgroup.com/226f3j00QShPJLAdkjUD/Transfer-Controller-Generation-Inverter-Changeover-Switch-Solar-and-Grid-Automatic-Transfer-Switch-220V-110V.webp)
![Transfer Controller Generation Inverter Changeover Switch Solar and Grid Automatic Transfer Switch 220V 110V](http://img9.grofrom.com/www.yselectricgroup.com/226f3j00TjVHJcdMlsGD/Transfer-Controller-Generation-Inverter-Changeover-Switch-Solar-and-Grid-Automatic-Transfer-Switch-220V-110V.webp)
![Transfer Controller Generation Inverter Changeover Switch Solar and Grid Automatic Transfer Switch 220V 110V](http://img9.grofrom.com/www.yselectricgroup.com/226f3j00EKVHdjmILsGP/Transfer-Controller-Generation-Inverter-Changeover-Switch-Solar-and-Grid-Automatic-Transfer-Switch-220V-110V.webp)
Application
Off grid solar, wind or hydro generator system; or standby battery pack.
![Transfer Controller Generation Inverter Changeover Switch Solar and Grid Automatic Transfer Switch 220V 110V](http://img9.grofrom.com/www.yselectricgroup.com/226f3j00tShPAdwcSKRL/Transfer-Controller-Generation-Inverter-Changeover-Switch-Solar-and-Grid-Automatic-Transfer-Switch-220V-110V.webp)
![Transfer Controller Generation Inverter Changeover Switch Solar and Grid Automatic Transfer Switch 220V 110V](http://img9.grofrom.com/www.yselectricgroup.com/226f3j00GZVIJfwrZKYL/Transfer-Controller-Generation-Inverter-Changeover-Switch-Solar-and-Grid-Automatic-Transfer-Switch-220V-110V.webp)
![Transfer Controller Generation Inverter Changeover Switch Solar and Grid Automatic Transfer Switch 220V 110V](http://img9.grofrom.com/www.yselectricgroup.com/226f3j00fsiImPwJMSRD/Transfer-Controller-Generation-Inverter-Changeover-Switch-Solar-and-Grid-Automatic-Transfer-Switch-220V-110V.webp)